    Thermo BioMate 3 Provides convenient, accurate UV-Vis measurements for life science laboratories
    Accurate, Reliable Performance for Life Science Laboratories
    The BioMate 3 is a grating-based spectrophotometer that can also be used as a general purpose instrument to measure other life science applications such as kinetics or multiwavelength analysis. In addition, it includes built-in software that will run performance verification measurements of photometric accuracy, wavelength accuracy, noise and stray light.
    The instruments feature the unique SmartStart
    TM
    screen that lets you select one, two or more pre-selected protocols. Turn on the instrument and the boot-up screen shows the selected tests ™ without additional scrolling.
    DNA ratio and concentration, with or without scanning
    Protein standard curves for Bradford, Lowry, BCA and Biuret reagents
    Direct UV concentrations of dsDNA, ssDNA, RNA and oligonucleotides
    Warburg-Christian method for measuring protein concentration
    Cell growth
    Oligo calculations for absorptivity, concentration factor, theoretical Tm values from a user-entered base sequence
    Hardware Designed for Performance
    Improved, 1.8nm spectral bandwidth is compliant with worldwide Pharmacopeia requirements, allowing research quality measurements with routine simplicity
    Patented optical design provides a compact, high-performance dual-beam system with very few moving parts
    Xenon lamp gives balanced light over the full instrument wavelength range of 190 to 1100nm
    Dual-beam optical system includes an internal reference detector and offers significant advantages over a single beam or diode array instruments, including compensation for lamp intensity changes, better performance for kinetics, and better long-term stability
    BioMate 3 ™
    DNA/RNA and protein analyzer
    High quality optics that include a long-life xenon lamp for stability and drift-free readings. No warm-up time required!
    A large 3.5™ x 2.5™ LCD displays current sample position, date and time, test parameters, graphs and data
    Models with 6-position cell changer for faster sample throughput
    Optional 3™ 40-column printer shows all parameters, graphs and data
    Includes seven additional test protocols including absorbance ratio, kinetics and survey scan
    Optional ultra-microcells with 40µL and 10µL chamber volume
    Sipper system for faster sample throughput
    Unit is ideal for DNA/RNA and protein analysis
    Optional built-in
    3
    in. (7.6cm) graphical printer shows test parameters, graph, and data
    Optional automatic six-position cell holder speeds up cell growth measurements or standard curve preparations
    Pre-programmed life science assays include:
    Nucleic acid ratio and concentration (260/280 and 260/2
    3
    0)
    Direct protein concentration at 280nm and 205nm
    Coomassie*/Bradford (Standard and Micro)
    Lowry
    BCA
    Pierce Micro-BCA
    Pierce 660nm Protein Assay
    Cell growth (with scaling factor)
    Kinetics
    Software Enhanced Flexibility
    Embedded software provides pre-programmed assays for RNA/DNA concentration or purity estimation, protein concentrations, cell growth, kinetics, or routine measurements
    For more intense applications, optional application software programs allow more sophisticated data collection, analysis, and reporting
    Time-Saving Bioanalysis Software
    Pre-programmed assays deliver fast, accurate results
    Built-in assays for nucleic acid concentration and purity estimations, protein concentration, and cell growth at 600nm
    Flexible Oligo calculator feature for calculating molecular weight, theoretical Tm and Oligo concentration factor
    Other standard applications include single and multicell kinetics, wavelength scanning, and user-defined fixed wavelength measurements
    Comes with USB Flash Drive, set of 2 Scinteck Brand Quartz Cuvettes, Operations Manual, and Power Cable.
    Specifications                                                                            335905
    Optics
    Split-beam, quartz-coated optics
    Lamp
    Long-life xenon
    Wavelength Range
    190–1100nm
    Wavelength Accuracy
    ±1.0nm
    Bandwidth
    5nm
    LCD
    Large 3.50 x 2.50 in. (8.9 x 6.4cm), shows all data and final results
    Noise
    <0.001A
    Scan Speed
    Survey scan (100nm increments)
    RS-232-C Interface
    Bidirectional RS-232-C
    Stability
    <0.001A/hr.
    Stray Light
    <0.1%T at 220 and 340nm
    Dimensions
    16 x 13 x 9 in. (41.0 x 33.0 x 23.0cm)
    Weight
    19 lb. (8.6kg)