T9/T10DCS Double Monochromator UV-Vis SpectrophotometerThe T9/T10DCS Spectrophotometer incorporates dual monochromator technology making it well suited to even the most demanding of applications in all areas of UV-Visible Spectroscopy.
The optical design of both the T9DCS and T10DCS offer extremely low stray light characteristics (≤0.00004%T NaI,220 nm) which allows for an extensive photometric range (-8.0 – 8.0Abs). Measurements at deep ultra-violet wavelengths can also be achieved with use of Nitrogen purged optics.
The instrument can be optically configured to suit the needs of the sample by means of a continually adjustable slit for precise control of spectral resolution and beam size adjustment by means of an attenuating wheel.
True Double Beam Double monochromator Optics, and fully sealed to provide ultra-low stray light (0.00004%%T @220nm) and high photometric range (-8.0~8.0 Abs)
185– 900nm Wavelength range with Nitrogen purge
Precise Wavelength accuracy is ensured by the integrated Mercury lamp for automatic correction
Continuously selectable spectra bandwidth from 0.1-5nm
Beam size continuously adjustable for variety of applications including ultra-volume cuvettes
Large sample compartment suitable for all kinds of accessories, especially for 150mm integrating sphere
Supports Wi-Fi communication in field operation
The integrated Mercury Emissions Lamp with automatic correction function ensures precise wavelength accuracy
Specifications
Model
T9DCS
T10DCS
Optical System
Double beam
Double beam
Scan Speed
1000 nm/min
1500 nm/min location speed
1000 nm/min
1500 nm/min location speed
Wavelength Range
185-900 nm
185-900 nm
Wavelength Accuracy
±0.2 nm
±0.2 nm
Spectral Bandwidth
±20 % (0.1 nm-5 nm continuously adjustable)
±20 % (0.1 nm-5 nm continuously adjustable)
Photometric Mode
Transmittance, Absorbance,
Energy and Concentration
Transmittance, Absorbance,
Energy and Concentration
Photometric Range
-6.0 Abs-6.0 Abs
-8.0 Abs-8.0 Abs
Photometric Accuracy
±0.004 [email protected] A
±0.003 [email protected] A
±0.002 [email protected] A
±0.3 %
±0.004 [email protected] A
±0.003 [email protected] A
±0.002 [email protected] A
±0.3 %
Photometric Reproducibility
≤0.002 [email protected] A
≤0.0008 A/1.0 A
≤0.0004 A/0.5 A
≤0.1 %
≤0.002 [email protected] A
≤0.0008 A/1.0 A
≤0.0004 A/0.5 A
≤0.1 %
Photometric Noise
0 % Noise: ≤0.01 %
100 % Noise: ≤0.1 %
0 % Noise: ≤0.01 %
100 % Noise: ≤0.1 %
Baseline Flatness
±0.0008 Abs
±0.0005 Abs
Baseline Stability
0.1 %/hr
0.1 %/hr
Stray light
≤0.0001 %T (NaI, 220 nm)
≤0.0001 %T (NaNO
2
, 360 nm)
≤0.00004 %T (NaI, 220 nm)
≤0.00002 %T (NaNO
2
, 360 nm)
Cell Holder
Automatic 8 Cell Changer
Automatic 8 Cell Changer
Detector
Photo multiplier tube
Photo multiplier tube
Light Source
D2 lamp, Tungsten lamp, Mercury lamp for WL correction
D2 lamp, Tungsten lamp, Mercury lamp for WL correction
PC Interface
RS232, USB, WIFI
RS232, USB, WIFI
Software Support
UV Win
UV Win
Power Supply
Switchable 120-230 VAC 50-60 Hz
Switchable 120-230 VAC 50-60 Hz
Weight
136 lb.
136 lb.
Dimensions
(Width, Depth, Height)
36 x 25 x 12 in
36 x 25 x 12 in
Optional Accessories are Available. Please inquire !
We Do ship with Airfreight, DHL International and FedEx : Please contact for International shipping