    UV-2550 Ultra-low stray light in the world's best double monochromator instrument
    Following their introduction in 1995, the world's highest performance, easy-to-use Shimadzu UV-2401/2501 spectrophotometers are now even more powerful with the addition of the world's most advanced software. These spectrophotometers have made their entrance to greet the new century.
    Whats included: Complete System
    206-25165-92    UV-2550PC Spectrophotometer
    220-92900-00    UV Probe Software Package.
    220-97318-10    Dell PC workstation T3500-W3503 with Keyboard, Mouse software.
    206-23790-94    Sipper Unit 160U (Super-micro Sipper)
    T22W                 22" Envision LCD Monitor
    Shimadzu UV-2550 UV-Vis Spectrophotometer
    Shimadzu UV-2550
    The Shimadzu UV-2550, with it's double-blazed grating, double monochomator design, provides a high-energy throughput optical system with ultra-low stray light. While featuring low stray light, excellent energy characteristics are provided over an extremely wide wavelength range (200 - 1100 nm), from the ultraviolet to visible, and into the near infrared for both liquid and solid samples.
    Use of this instrument is currently determined on a case-by-case basis by the LSBI administration, and it is not available to all LSBI users.  Researchers interested in utilizing this instrument, please send a brief email outlining your intended research needs to the LSBI Director,
    Professor Karen Wooley
    .  If you are approved to use the instrument, instructions on how to proceed will be sent via email from the LSBI administration.
    Low stray light
    The UV-2550, with its DDM (double blazed grating, double monochromator) design, provides a high energy throughput optical system with ultra low stray light. The UV-2450, the single monochromator version of the UV-2550, achieves 0.015% stray light even with its simpler optical system.
    High Performance
    Both instruments offer outstanding cost performance in their ability to provide UV-VIS spectral analysis of wide ranging samples, including organic and inorganic compounds, biological samples like DNA and enzymes, as well as special measurements on optical materials.
    Windows XP Pro/2000 Pro Compatible
    Operating under the Windows XP Pro/2000 Pro environment, the new generation UV Probe software is provided as standard. UVProbe incorporates the latest multitasking and report generation functionality, including network support, enabling measurement assistance among colleagues and effective presentation of precious data.
    Analysis of multiple trace samples
    The 8/16 micromulti-cell permits selection among 4 possible combinations with sample capacities of 50mL and 100mL. And, either the normal type or the constant-temperature controlled type cell holder may be selected.
    High energy over a wide wavelength Newly developed optics open up
    UV-2550
    [-] Hide Specifications
    UV-2550
    Wavelength
    Range
    190 to 900nm (performance guaranteed range). Extendable to 1,100nm through the use of the optional photomultiplier. (The measurable range maybe restricted in the shorter wavelength side depending on the type of photomultipler used.)
    Monochromator System
    UV-2450: Single monochromator with a high-performance blazed holographic grating in the aberration corrected Czerny-Turner mounting.
    UV-2550: Double monochromator with a high-performance double-blazed holographic grating in the aberration corrected Czerny-Turner mounting.
    Resolution
    0.1nm
    Spectral Bandwidth
    0.1, 0.2, 0.5, 1, 2 and 5nm
    Wavelength Accuracy
    ±0.3nm
    Wavelength Repeatability
    ±0.01nm
    Wavelength Scanning Speed
    FAST, MEDIUM, SLOW, and SUPER SLOW
    Light Source
    50W halogen lamp (2,000 hours of life) and D
    2
    lamp (500 hours of life)
    Light Source lamp switching
    Selectable between 282nm and 393nm
    Stray Light
    UV-2550: Less than 0.0003% at 220nm and 340nm
    Detector
    Photomultiplier R-928
    Photometric System
    Double beam, direct ratio system with dynode feedback
    Photometric Mode
    Absorbance (Abs.), transmittance (%), reflectance (%) and energy (E).
    Photometric Range
    Abosrbance: -4~5 Abs. (0.001 Abs. increments)
    Transmittance: 0~999.9% (0.01 increments)
    Reflectance: 0~999.9% (0.01% increments)
    Photometric Accuracy
    ±0.002Abs(0~0.5Abs), ±0.004Abs(0.5~1Abs),±0.3T (0~100%T)
    (all determined with NIST 930D standard filter)
    Photometric Repeatability
    0.001Abs (0~0.5Abs), ±0.1%T
    Baseline Correction
    Selectable with storage in firmware
    Baseline Flatness
    Within ±0.001Abs.
    (excluding noise, 2nm slit width and SLOW wavelength scanning speed)
    Drift
    Less than 0.0004 Abs. per hour (after 2 hours warm-up)
    Dimensions
    570 (W) x 660 (D) x 275 (H) (mm)
    Weight
    36kg
    Power Supply
    AC 100V/120V/220V/240V,
    50/60Hz 250VA (
    switch
    -selectable)