-40%

MKS PPT-100-FC RGA Quadrupole Residual Gas Analyzer 100 amu, Spectrometer

$ 659.99

Availability: 36 in stock
  • Condition: The unit is in like-new condition with some minor scuffs. It is sold as-is, where-is, untested.
  • Brand: MKS
  • All returns accepted: ReturnsNotAccepted
  • Type: Residual Gas Analyzer
  • MPN: PPT-100-FC
  • Model: PPT-100-FC

    Description

    NEW MKS PPT-100-FC Partial Pressure Transducer / Quadrupole RGA Residual Gas Analyzer - 100 amu
    Comes with a manual and what you see in the pictures. If you don't see it, you probably wont get it.
    Specifications are from MKS and may vary slightly due to upgrades, options, or revisions this unit may or may not have.
    The unit is in like-new condition with some minor scuffs. It is sold as-is, where-is, untested.
    List Price was:
    Approx. ,250.00 new.
    Unit's Serial Number Tag Reads:
    Part Number:
    PPT-100-FC
    Serial Number:
    1243-S9605
    Features & Benefits:
    Mass Range to 100 amu
    - High molecular weight determination.
    Faraday and Electron Multiplier Detectors
    - Operation to UHV.
    Compact, Cost-Effective Design
    - Reduces equipment cost, minimizes installation cost, and eliminates rack space requirements.
    Easy-to-use Software
    - Controlled by a standard Windows OS PC.
    Operational Advantages
    - Gains insight into vacuum system operation, improves quality and yields, and increases uptime.
    Applications:
    Residual Gas Analysis
    Leak Detection
    Particle Accelerators
    Synchrotron Rings
    Surface Science
    Thermal Desorption
    TGA Gas Evolution
    Catalytic Studies
    CVD/MOCVD/PECVD
    Molecular Beam Epitaxy
    Ion Beam Milling
    Ion Implantation
    Vacuum Coating
    Vacuum Heat Treating
    Monitoring Gas-filled Devices
    Gas Reaction Experiments
    Description:
    The NGS PPT (Partial Pressure Transducer) Series is the first RGA design to combine the traditionally large (and expensive) control electronics modules into a single, lower-cost compact ECU (Electronics Control Unit) that mounts directly on the quadrupole sensor flange. The basic system, consisting only of the quadrupole sensor and ECU, interfaces directly with PC-compatible computers via the standard RS-232 port. The ECU requires 24 VDC for operation.
    Quadrupole-based residual gas analyzers work by ionizing, separating, and detecting ions in order to determine the partial pressures of gases in a vacuum system. As shown above, ions, generated at the ion source, are focused through the quadrupole entrance aperture and then mass-filtered by the quadrupole filter rods. The mass-filtered ions are measured as an ion current at the detector.
    The quadrupole sensor requires a pressure lower than 1 x 10
    -4
    Torr for operation. Accordingly, in high vacuum and ultra-high vacuum applications the quadrupole sensor is normally mounted directly on the vacuum chamber. For atmospheric, rough vacuum, and medium vacuum applications a pumping system and pressure reduction manifold is required.
    Easy-to-Use Software:
    Unlike many other RGA software programs, the NGS PPT Series software is designed for ease of use. The program is menu-driven and is designed for on-screen editing. Full-color EGA/VGA graphics allow easy interpretation and use by operators unfamiliar with the equipment.
    Beyond ease-of-use, the NGS PPT software has several different modes of operation, fast-capture real-time graphing, and a user-settable alarm option. For off-line data manipulation, data files can be created in ASCII file format, so the spreadsheet programs such as Lotus 1-2-3 and Microsoft Excel may be used to maintain test data and perform statistical analysis.
    Inteligent Design:
    Compact size
    is possible through the use of a quadrupole sensor flange-mounted ECU, measuring only 9.50" L x 4.50" D x 5.00" H.
    Excellent mass resolution
    is attained through precision machines quadrupole rod sets and alumina ceramics.
    Easy maintenance
    is designed-in through simple ion source construction and an easy filament replacement procedure. To minimize maintenance requirements, the PPT uses oxide-coated iridium filaments, which can withstand accidental vacuum overpressures.
    Performance stability
    is maintained by the use of a continuous dynode electron multiplier detector that does not degrade when exposed to air, unlike discrete dynode types. Furthermore, unlike channel plate detectors, the NGS continuous dynode electron multiplier is not prone to failure through dust and particle contamination.
    Intelligent Manufacture:
    Contamination of your system
    is avoided and
    calibration stability is improved
    by a 24-hour bakeout cycle before quadrupole sensor calibration.
    Calibration accuracy
    is provided by calibrating the quadrupole against an MKS Spinnings Rotor Gauge (SRG, not provided). The calibration of the SRG is directly traceable to NIST. With an accuracy of 1% of Reading +/- 3 x 10
    -8
    Torr, the SRG is about ten times more accurate than hot filament gauges commonly used by other manufactures to calibrate RGA's.
    Even pressure/temperature distribution throughout the vacuum manifold
    is achieved because the RGA calibration stand manifolds are designed in accordance with the ISO / DIN 3567 standard.
    Performance Specifications:
    Max. Operating Pressure:
    1 x 10
    -4
    Torr
    Resolution:
    10% Valley (per AVS Standard 2.3)
    Sensitivity:
    2.5 x 10
    -4
    Amps/Torr
    Emission Current:
    1000µ Amps standard
    Electron Energy:
    75 volts standard
    Minimum Detectable Partial Pressure:
    Faraday Cup:
    2 x 10
    -11
    Torr
    Electron Multiplier:
    5 x 10
    -14
    Torr
    Max. Quadrupole Sensor Bakeout Temperature:
    300°C up to 24 hrs., 250°C up to 7 days.
    ECU Operating Temperature:
    0° - 40°C
    Electrical Specifications:
    Standard Interfaces:
    RS-232 and BitBus, 2 analog outputs
    External Control:
    For emission and scanning, opto-isolated, 5 to 24 VDC input and two active lows are required
    Power Requirements:
    24 Volts @ 2 Amps (voltage tolerance: +10% / -5%)
    Computer Specifications:
    80286 or higher; Microsoft MS-DOS 3.3 or later
    Mechanical Specifications:
    Mass Filter Pole Dia.:
    0.25" (6.35 mm)
    Mass Filter Length:
    5.5" (140 mm)
    Filament Options:
    Oxide-coated iridium (standard); tungestn, rhenium (optional)
    Mounting Flange:
    2.75" CF (DN35CF)
    Other Specifications:
    Total Pressure Measurement:
    Integral ion source electrode
    Vacuum Protection:
    Filament and electron multiplier protection using total pressure measurement
    Calibration:
    Against Spinning Rotor Gauge, nitrogen at m/e 28
    Calibration Chamber:
    Meets requirements of ISO / DIN 3567
    For Domestic Customers: Packaging, handling, and order processing included in shipping in all domestic shipments as quoted by the shipping calculator. For International Customers there is a .00 minimum for packaging, handling, and order processing. International shipping to be determined by destination.
    Prior to shipment I will need to know the following information (filled out on a form that I will send you) for International Customers or Packages/Freight being Forwarded internationally. International customers may also be subject to a freight forwarder form if applicable.:
    (1) Are you the end-user of this item?
    (2) If you are not the ultimate end-user of the item, please state the ultimate end user's name.
    (3) What is the ultimate country destination?
    07/11/06