MKS PPT-100-FC RGA Quadrupole Residual Gas Analyzer 100 amu, Spectrometer
$ 659.99
- Description
- Size Guide
Description
NEW MKS PPT-100-FC Partial Pressure Transducer / Quadrupole RGA Residual Gas Analyzer - 100 amuComes with a manual and what you see in the pictures. If you don't see it, you probably wont get it.
Specifications are from MKS and may vary slightly due to upgrades, options, or revisions this unit may or may not have.
The unit is in like-new condition with some minor scuffs. It is sold as-is, where-is, untested.
List Price was:
Approx. ,250.00 new.
Unit's Serial Number Tag Reads:
Part Number:
PPT-100-FC
Serial Number:
1243-S9605
Features & Benefits:
Mass Range to 100 amu
- High molecular weight determination.
Faraday and Electron Multiplier Detectors
- Operation to UHV.
Compact, Cost-Effective Design
- Reduces equipment cost, minimizes installation cost, and eliminates rack space requirements.
Easy-to-use Software
- Controlled by a standard Windows OS PC.
Operational Advantages
- Gains insight into vacuum system operation, improves quality and yields, and increases uptime.
Applications:
Residual Gas Analysis
Leak Detection
Particle Accelerators
Synchrotron Rings
Surface Science
Thermal Desorption
TGA Gas Evolution
Catalytic Studies
CVD/MOCVD/PECVD
Molecular Beam Epitaxy
Ion Beam Milling
Ion Implantation
Vacuum Coating
Vacuum Heat Treating
Monitoring Gas-filled Devices
Gas Reaction Experiments
Description:
The NGS PPT (Partial Pressure Transducer) Series is the first RGA design to combine the traditionally large (and expensive) control electronics modules into a single, lower-cost compact ECU (Electronics Control Unit) that mounts directly on the quadrupole sensor flange. The basic system, consisting only of the quadrupole sensor and ECU, interfaces directly with PC-compatible computers via the standard RS-232 port. The ECU requires 24 VDC for operation.
Quadrupole-based residual gas analyzers work by ionizing, separating, and detecting ions in order to determine the partial pressures of gases in a vacuum system. As shown above, ions, generated at the ion source, are focused through the quadrupole entrance aperture and then mass-filtered by the quadrupole filter rods. The mass-filtered ions are measured as an ion current at the detector.
The quadrupole sensor requires a pressure lower than 1 x 10
-4
Torr for operation. Accordingly, in high vacuum and ultra-high vacuum applications the quadrupole sensor is normally mounted directly on the vacuum chamber. For atmospheric, rough vacuum, and medium vacuum applications a pumping system and pressure reduction manifold is required.
Easy-to-Use Software:
Unlike many other RGA software programs, the NGS PPT Series software is designed for ease of use. The program is menu-driven and is designed for on-screen editing. Full-color EGA/VGA graphics allow easy interpretation and use by operators unfamiliar with the equipment.
Beyond ease-of-use, the NGS PPT software has several different modes of operation, fast-capture real-time graphing, and a user-settable alarm option. For off-line data manipulation, data files can be created in ASCII file format, so the spreadsheet programs such as Lotus 1-2-3 and Microsoft Excel may be used to maintain test data and perform statistical analysis.
Inteligent Design:
Compact size
is possible through the use of a quadrupole sensor flange-mounted ECU, measuring only 9.50" L x 4.50" D x 5.00" H.
Excellent mass resolution
is attained through precision machines quadrupole rod sets and alumina ceramics.
Easy maintenance
is designed-in through simple ion source construction and an easy filament replacement procedure. To minimize maintenance requirements, the PPT uses oxide-coated iridium filaments, which can withstand accidental vacuum overpressures.
Performance stability
is maintained by the use of a continuous dynode electron multiplier detector that does not degrade when exposed to air, unlike discrete dynode types. Furthermore, unlike channel plate detectors, the NGS continuous dynode electron multiplier is not prone to failure through dust and particle contamination.
Intelligent Manufacture:
Contamination of your system
is avoided and
calibration stability is improved
by a 24-hour bakeout cycle before quadrupole sensor calibration.
Calibration accuracy
is provided by calibrating the quadrupole against an MKS Spinnings Rotor Gauge (SRG, not provided). The calibration of the SRG is directly traceable to NIST. With an accuracy of 1% of Reading +/- 3 x 10
-8
Torr, the SRG is about ten times more accurate than hot filament gauges commonly used by other manufactures to calibrate RGA's.
Even pressure/temperature distribution throughout the vacuum manifold
is achieved because the RGA calibration stand manifolds are designed in accordance with the ISO / DIN 3567 standard.
Performance Specifications:
Max. Operating Pressure:
1 x 10
-4
Torr
Resolution:
10% Valley (per AVS Standard 2.3)
Sensitivity:
2.5 x 10
-4
Amps/Torr
Emission Current:
1000µ Amps standard
Electron Energy:
75 volts standard
Minimum Detectable Partial Pressure:
Faraday Cup:
2 x 10
-11
Torr
Electron Multiplier:
5 x 10
-14
Torr
Max. Quadrupole Sensor Bakeout Temperature:
300°C up to 24 hrs., 250°C up to 7 days.
ECU Operating Temperature:
0° - 40°C
Electrical Specifications:
Standard Interfaces:
RS-232 and BitBus, 2 analog outputs
External Control:
For emission and scanning, opto-isolated, 5 to 24 VDC input and two active lows are required
Power Requirements:
24 Volts @ 2 Amps (voltage tolerance: +10% / -5%)
Computer Specifications:
80286 or higher; Microsoft MS-DOS 3.3 or later
Mechanical Specifications:
Mass Filter Pole Dia.:
0.25" (6.35 mm)
Mass Filter Length:
5.5" (140 mm)
Filament Options:
Oxide-coated iridium (standard); tungestn, rhenium (optional)
Mounting Flange:
2.75" CF (DN35CF)
Other Specifications:
Total Pressure Measurement:
Integral ion source electrode
Vacuum Protection:
Filament and electron multiplier protection using total pressure measurement
Calibration:
Against Spinning Rotor Gauge, nitrogen at m/e 28
Calibration Chamber:
Meets requirements of ISO / DIN 3567
For Domestic Customers: Packaging, handling, and order processing included in shipping in all domestic shipments as quoted by the shipping calculator. For International Customers there is a .00 minimum for packaging, handling, and order processing. International shipping to be determined by destination.
Prior to shipment I will need to know the following information (filled out on a form that I will send you) for International Customers or Packages/Freight being Forwarded internationally. International customers may also be subject to a freight forwarder form if applicable.:
(1) Are you the end-user of this item?
(2) If you are not the ultimate end-user of the item, please state the ultimate end user's name.
(3) What is the ultimate country destination?
07/11/06