-40%
Konica Minolta Benchtop Spectrophotometer CM-5 with Accessories
$ 5543.47
- Description
- Size Guide
Description
Excellent condition as shown in photos. Looks brand new. Powers on and goes through self calibration perfectly. Tested as shown but no additional testing done beyond that. Accessories shown and SpectraMagic NX software included. Will be packed and shipped in original box.An advanced all-in-one system, the CM-5 Spectrophotometer is a bench-top measurement instrument designed to evaluate the color and appearance of opaque, transparent, and translucent samples. Its high precision and advanced capabilities allow users to effectively analyze, formulate, and control the color and appearance of solids, liquids, pastes, powders, pills, and granules in a more comprehensive, streamlined process. This makes the CM-5 ideal for color analysis within R&D and laboratory environments.
Used as a standalone instrument, the CM-5 is also compatible with SpectraMagic NX software to record measurements and provide a more comprehensive color analysis, as well as Colibri software to formulate color recipes for various applications.
Features
Eligible ISO 17025 Certification
Includes aperture sizes, 3mm, 8mm, and 30mm, to evaluate the color and appearance of samples very small to large in size
Equipped with a top-port area for measuring opaque samples, as well as a transmittance chamber for measuring transparent and translucent samples
Pass/fail assessments immediately determines if the sample meets the defined standard or target color
Instrument is calibrated automatically with each start up to maintain its high accuracy and performance
Large color LCD screen displays data and graphs clearly, including color values, spectral graphs, and color difference graphs, for interpretation of measurement results
Provides an Operation Wizard to guide users through instrument set up and measurement use
Individual instrument settings and measurement data can be stored to eliminate confusion between multiple users
Various industry-specific indices are stored in the instrument, including Gardner, Hazen/APHA, Iodine Color Number, US and European Pharmacopoeia, to meet application needs quickly and more effectively
8 language options includes English, Spanish, German, Italian, French, Portuguese, Japanese, and simplified Chinese
Stores measurement results and displays data numerically and in graph charts, eliminating the need for a computer; can be integrated with SpectraMagic NX software to provide a more comprehensive color analysis, as well as Colibri software to formulate color recipes for various applications
Specifications
Model
CM-5
Illumination/viewing system
Reflectance:
di:8 °, de:8 ° (diffuse illumination: 8 ° viewing)
SCI (specular component included)/SCE (specular component excluded) switchable
Conforms to CIE No. 15, ISO 7724/1, ASTM E 1164, DIN 5033 Teil 7, and JIS Z 8722 (Condition c)
Transmittance:
di:0 °, de:0 ° (diffuse illumination: 0 ° viewing)
Integrating sphere size
Φ152 mm
Detector
Dual 40-element silicon photodiode arrays
Spectral separation device
Planar diffraction grating
Wavelength range
360 nm to 740 nm
Wavelength pitch
10 nm
Half bandwitdh
Approx. 10 nm
Measurement range
0 to 175 % (Reflectance or transmittance); Output/display resolution: 0.01%
Light source
Pulsed xenon lamp
Measurement time
Approx. 1 s (to data display/output); Minimum measurement interval: Approx. 3 s
Measurement/illumination area
Reflectance:
Changeable by changing mask and settings. LAV:Φ30 mm/Φ36 mm; MAV (optional):Φ8 mm/Φ11 mm; SAV (optional):Φ3 mm/Φ6 mm
Transmittance:
Φ26 mm
Repeatability
Spectral reflectance: Standard deviation within 0.1% (400 nm to 740 nm)
Chromaticity value: Standard deviation within ΔE*ab 0.04 * When a white calibration plate is measured 30 x at 10-second intervals after white calibration
Inter-instrument agreement
Within ΔE*ab 0.15 (Typical) (LAV/SCI)
(Based on 12 BCRA Series II color tiles compared to values measured with a master body under Konica Minolta standard conditions)
Transmittance chamber
No sides (unlimited sample length); Depth (maximum sample thickness): 60 mm
Sample holders (optional) for holding sheet samples or containers of liquid samples can be installed/removed
Display
5.7-inch TFT color LCD
Display languages
English, Japanese, German, French, Italian, Spanish, Simplified Chinese, Portuguese
Operating temperature/humidity range
13 to 33 °C, relative humidity 80% or less with no condensation
White/100% calibration
Automatic white (reflectance)/100% (transmittance) calibration using internal white calibration plate
(Not applicable to 100% calibration when using cells for transmittance measurements of liquids.)
Interfaces
USB 1.1 (Connection to PC; USB memory stick); RS-232C standard (Connection to serial printer)
Observer
2 ° Standard Observer or 10 ° Standard Observer
Illuminant
A, C, D50, D65, F2, F6, F7, F8, F10, F11, F12, ID50, ID65 (simultaneous evaluation with two light sources possible)
Displayed data
Spectral values/graph (reflectance, transmittance, absorbance), colorimetric values/graph, color-difference values/graph, pass/fail judgment, pseudo color, color assessment
Color space
L*a*b*, L*C*h, Hunter Lab, Yxy, XYZ, Munsell, and color differences in these spaces (except for Munsell)
Index
Reflectance:
MI; WI (ASTM E 313-73, ASTM E 313-96); YI (ASTM E 313-73, ASTM E 313-96, ASTM D 1925);
ISO Brightness; B (ASTM E 313-73)
Transmittance:
Gardner; Iodine Color Number; Hazen/APHA; European Pharmacopoeia; US Pharmacopeia
User index
User-defined index
Color-difference equation
ΔE*ab (CIE 1976), ΔE*94 (CIE 1994), ΔE00 (CIE 2000), ΔE (Hunter), CMC (l: c)
Pass/fail judgment
Tolerances can be set to colorimetric values (except Munsell), color-difference values, or reflectance index values
Storable data
Measurement data: 4,000 measurements; Target color data: 1,000 measurements
USB memory stick* storage
Storage of measurement data and target color data. Storage/reading of measurement condition settings
* Security-enabled USB memory sticks cannot be used.
Power
AC 100 to 240 V, 50/60 Hz (using exclusive AC adapter)
Size
Slide cover closed: 385 (W) x; 192 (H) x; 261 (D) mm
Slide cover open: 475 (W) x; 192 (H) x; 261 (D) mm
Weight
Approx. 5.8 kg
Operating temperature/humidity range
13 to 33 °C, relative humidity 80 % or less (at 33 °C) with no condensation
Storage temperature/ humidity range
0 to 40 °C, relative humidity 80 % or less (at 33 °C) with no condensation